Danh mục sản phẩm

Meanwell LRS-350-4.2 4.2V60A 252W Input Voltage Selectable LED Power Supplies

(0 lượt đánh giá)     Model:      Lượt xem: 48      Tình trạng hàng: Còn hàng
Đặc điểm nổi bật
Meanwell LRS-350-4.2 4.2V60A 252W Input Voltage Selectable LED Power Supplies Meanwell LRS-350-4.2 4.2V60A 252W Input Voltage Selectable LED Power Supplies Description: In addition to the high efficiency up to 89%, with the built-in long life fan LRS-350 can work under -25~+70℃ with full load. Delivering an extremely low no load power consumption (less than 0.75W), it allowsthe end system to easily meet the worldwide energy requirement. LRS-350 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as UL60950-1. LRS-350 series serves as a high price-to-performance power supply solution for various industrial applications.
Xem thêm
Bảo hành: 6 Tháng
Chúng tôi cam kết:
Hàng chính hãng
Thanh toán linh hoạt
Bảo hành tại nơi sử dụng
Giao hàng toàn quốc
Tư vấn - đặt hàng
Ms Thảo: 0902.671.187
Ms Minh: 0909.555.709
Ms Vi: 0938.522.652
Mr Cường: 0932.680.356
Ms Hương: 0937.121.802
Thông số kỹ thuật Đặc điểm nổi bật Video Sản phẩm tương đương Bình luận người dùng Đánh giá sản phẩm

Video

Meanwell LRS-350-4.2 4.2V60A 252W Input Voltage Selectable LED Power Supplies

 

 

Để biết thêm thông tin chi tiết xin vui lòng liên hệ với chúng tôi:

Công ty TNHH Truyền Thông Tùng Việt

Địa chỉ: 489A/21/54 Huỳnh Văn Bánh, Phường 13, Quận Phú Nhuận, TP.HCM, VN

Hotline: 0909.555.709
https://manhinhquangcao247.com/
https://vietnamdigitalsignage.com/

Xem thêm

Meanwell LRS-350-4.2 4.2V60A 252W Input Voltage Selectable LED Power Supplies

0/5

0 đánh giá & nhận xét
  • 5 sao
    0
  • 4 sao
    0
  • 3 sao
    0
  • 2 sao
    0
  • 1 sao
    0

Bạn đã dùng sản phẩm này?

Gửi đánh giá của bạn

Gửi nhận xét của bạn

Gửi đánh giá Hủy

Le Tuan Anh 25/12/2020 23:13:31

Sản phẩm tuyệt vời

Hỏi đáp

Thông số kỹ thuật

Meanwell LRS-350-4.2 4.2V60A 252W Input Voltage Selectable LED Power Supplies Parameters:

MODEL

LRS-350-4.2

OUTPUT

DC VOLTAGE

4.2V

RATED CURRENT

60A

CURRENT RANGE

0 ~ 60A

RATED POWER

252W

RIPPLE & NOISE (max.) Note.2

150mVp-p

VOLTAGE ADJ. RANGE

3.6 ~ 4.4V

VOLTAGE TOLERANCE Note.3

±4.0%

LINE REGULATION Note.4

±0.5%

LOAD REGULATION Note.5

±2.5%

SETUP, RISE TIME

1500ms, 50ms/230VAC        1500ms,50ms/115VAC at full load

HOLD UP TIME (Typ.)

16ms/230VAC     12ms/115VAC at full load

INPUT

VOLTAGE RANGE

90 ~ 132VAC / 180 ~ 264VAC by switch         240 ~ 370VDC    (switch on 230VAC)

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

81.5%

AC CURRENT (Typ.)

6.8A/115VAC         3.4A/230VAC

INRUSH CURRENT (Typ.)

60A/115VAC        60A/230VAC

LEAKAGE CURRENT

<2mA / 240VAC

PROTECTION

OVER LOAD

110 ~ 140% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

 

OVER VOLTAGE

4.6 ~ 5.4V

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER TEMPERATURE

Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

WORKING TEMP.

RTH3≧50℃ FAN ON, ≦40℃ FAN OFF

WORKING HUMIDITY

-25 ~ +70℃ (Refer to "Derating Curve")

STORAGE TEMP., HUMIDITY

20 ~ 90% RH non-condensing

TEMP. COEFFICIENT

-40 ~ +85℃, 10 ~ 95% RH

VIBRATION

±0.03%/℃ (0 ~ 50℃)

SAFETY

SAFETY STANDARDS

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

WITHSTAND VOLTAGE

UL60950-1 approved

ISOLATION RESISTANCE

I/P-O/P:3KVAC    I/P-FG:2KVAC    O/P-FG:0.5KVAC

OTHERS

MTBF

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH

DIMENSION

327.9K hrs min.     MIL-HDBK-217F (25℃)

PACKING

215*115*30mm (L*W*H)

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 

47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Line regulation is measured from low line to high line at rated load.

5. Load regulation is measured from 0% to 100% rated load.

6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to 

increase of the set up

time.

7.The 150% peak load capability is built in for up to 1 second for 12~48V.LRS-350 will enter hiccup mode if the peak 

load is delivered

for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC).

8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).